Dr. Hirai was a Japanese engineer, professor, and researcher. In 1940, Dr. Hirai went to a movie theater and watched the news about the failure of the old Tacoma bridge. He was very inspired and started his research on wind engineering for suspension bridges by himself. His papers had been published since 1942, but they were rarely introduced into the Western world because Japan was isolated during World War II.
The basic step of wind engineering is eigenvalue analysis, and his method is as follows.
Model view
Assumed shape function
Center span
Vertical, Asymmetrical, 2nd mode, T=6.821 sec
Vertical, Asymmetrical, 4th mode, T=2.263 sec
Vertical, Asymmetrical, 1st mode, T=3.959 sec
Frequency equation
Assumed shape function
There are many ways to solve this frequency equation. The author’s favorite is the Stodola-Vianello method.
Vertical, Symmetrical, 1st mode, T=5.8733 sec (dashed line shows the 1st term)
Vertical, Symmetrical, 2nd mode, T=3.5699 sec (dashed line shows the 1st term)
Vertical, Symmetrical, 3rd mode, T=2.9019 sec (dashed line shows the 1st term)
In the first term, the warping term, and the third term, effects from cable tension are negligible in the lower modes as can be expected.
Torsional, Asymmetrical, 2nd mode, T=1.614 sec (red line shows rotational angle)
Torsional, Asymmetrical, 4th mode, T=0.778 sec (red line shows rotational angle)
Ritz’s methods, frequency equation is,
Torsional, Symmetrical, 1st mode, T=2.5640 sec (dashed line shows the 1st term)
Torsional, Symmetrical, 3rd mode, T=1.0767 sec (dashed line shows the 1st term)
Torsional, Symmetrical, 5th mode, T=1.0529 sec (dashed line shows the 1st term)
Assumed shape function
Frequency equation
Transverse, 1st mode, in-plane, T=13.31 sec (dashed line shows cable)
Transverse, 1st mode, out-of-plane, T=3.238 sec (dashed line shows cable)
Transverse, 2nd mode, in-plane, T=4.896 sec (dashed line shows cable)
Transverse, 2nd mode, out-of-plane, T=3.175 sec (dashed line shows cable)
For lower modes, transverse modes are very well matched, vertical modes have 10% to 23% differences. In the vibration analysis, only some lower modes are important.
From the author’s view, this classic method from Dr Hirai gives very reasonable results and it is an excellent tool to check the computer output. After we make a simple Excel, it is very easy to check for other geometry and/or loadings which takes some time with displacement methods.
Finally results from MIDAS are attached for the lower five modes.